NuMED (Canada) Inc

NuMED Inc, founded in Hopkinton, New York, USA in 1982, (Canada in 1990) consists of a manufacturing facility. This extrusion facility has experience working with and extruding a full range of catheter materials. It has a fully equipped Research and Development department, which is responsible for the design feasibility, FDA testing, and introduction of many catheter and stent designs. The Canadian facility caters the needs of over 50 countries worldwide wit export being 90% of the total product throughput. NuMED’s President, Mr Allen Tower sr has over 40 years experience in the cardio-vascular catheter field.


Products

 DHC High Five™

DHC High Five™

PTA ultra-high pressure catheter - Curved

 

Catheter Characteristics

The DHC High Five™ Curved PTA catheter is engineered for maximum steerability and pushability. The coaxial shaft design provides a proximal shaft with enhanced column strength for pushability and decreased distal shaft for optimum steerability. 

Read more
 
BIB® Stent Placement catheter

BIB® Stent Placement catheter

All Catheters have:

An inner balloon 1/2 of the balloon diameter of the outer balloon. i.e. BB010 has an 8.0 mm inner balloon.

An inner balloon that is 1.0 cm shorter than the outer balloon. i.e. BB010 has an inner balloon that is 2.0 cm long.

An inner balloon with a rated burst pressure of 4.5 to 5.0 atmospheres. Four image bands that match the functional length of each balloon.

A length of 110 cm.

Read more
 
Coefficient™ Pediatric Valvuloplasty catheter

Coefficient™ Pediatric Valvuloplasty catheter

Catheter Characteristics

The COEfficient™ Pediatric Valvuloplasty catheter is engineered for maximum steering and tracking. The coaxial shaft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability.

Radiopaque Marker

Platinum marker bands facilitate reliable positioning of the balloon.

Read more
 
CP Stent™ Dilatation catheter

CP Stent™ Dilatation catheter

Stent Characteristics

The CP Stent™ is composed of 0.013" platinum / iridium wire that is arranged in a “zig” pattern, laser welded at each joint and over brazed with 24K gold. It allows expansion from 8.0 mm to 24.0 mm. The Covered CP Stent™ is comprised of the Bare CP Stent that is covered with an expandable sleeve of ePTFE.

Read more
 
DH High Five™

DH High Five™

PTA ultra-high pressure catheter

 

Catheter Characteristics

The DH High Five™ PTA catheter is engineered for maximum steerability and pushability. The coaxial shaft design provides a proximal shaft with enhanced column strength for pushability and decreased distal shaft for optimum steerability. 

Read more
 
DSC™ Dialysis catheter - Curved

DSC™ Dialysis catheter - Curved

Catheter Characteristics

The DSC™ Curved Balloon is a Coaxial catheter used for dilatations of renal arteries and blocked dialysis shunts. The catheter features a 10.0 atmosphere balloon mounted on 4.5 or 5.5 french shaft.

Visualization

Two image bands are placed beneath the shoulders of the balloon to allow reliable positioning of the balloon within the stenosis.

Read more
 
DS™

DS™

Dialysis catheter - Straight

 

Catheter Characteristics

The DS™ Straight Balloon is a Coaxial catheter used for dilatations of renal arteries and blocked dialysis shunts. The catheter features a 10.0 atmosphere balloon mounted on 4.5 or 5.0 french shaft.

Read more
 
GHOST II™ Dilatation catheter

GHOST II™ Dilatation catheter

Catheter Characteristics

The Ghost II™ is a dual lumen catheter for use in PTA applications. The catheter features a high pressure, low profile balloon mounted on a 5.0 Fr shaft. This catheter is available in a wide variety of balloon lengths and diameters and also four different usable lengths. This catheter is not for use in the coronary arteries.

Read more
 
High Five™

High Five™

PTA ultra-high pressure catheter

 

Catheter Characteristics

The High Five™ PTA catheter is engineered for maximum steerability and pushability. The coaxial shaft design provides a proximal shaft with enhanced column strength for pushability and decreased distal shaft for optimum steerability.

Read more
 
MINI GHOST™ Dilatation catheter

MINI GHOST™ Dilatation catheter

Catheter Characteristics

The Mini Ghost™ is a coaxial catheter used for dilatations of small vessels. The catheter features a 20 or 12 ATM balloon mounted on 3.5 Fr shaft. The catheter is available in balloon diameters of 2.0mm to 6.0mm and also a variety of balloon and usable lengths. This catheter is not for use in the coronary arteries.

Read more
 
MULTI-TRACK™ Angiographic catheter

MULTI-TRACK™ Angiographic catheter

The MULTI-TRACK™ angiographic catheter utilizes a unique concept of guidewire location to increase flow rate and maneuverability of the catheters. Designed from radiopaque materials, the catheters are easily placed and can be used in conjunction with different types of interventional catheters.

Read more
 
Nucleus™ Percutaneous Transluminal Valvuloplasty catheter (Patent # 5,352,199)

Nucleus™ Percutaneous Transluminal Valvuloplasty catheter (Patent # 5,352,199)

Catheter Characteristics

The NuMED NuCLEUS™ PTV catheter is engineered for maximum steering and tracking. The coaxial shaft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability. The innovative single balloon design facilitates positive positioning while holding the balloon in the correct location prior to and during inflation.

Read more
 
PTS-X™ Sizing Balloon Catheter

PTS-X™ Sizing Balloon Catheter

Xtra high inner lumen strength Xtra fast guidewire movement (even with balloon inflated) Increased pushability from new braided inner tubing Radiopaque inner tubing Read more
 
PTS® Sizing Balloon Catheter

PTS® Sizing Balloon Catheter

Catheter Characteristics

The PTS® Sizing Balloon catheter has been designed for use in patients with cardiovascular defects where accurate measurement of the defect is important to select the appropriately sized occluder device.

Radiopaque Marker

Platinum marker bands facilitate reliable positioning of the balloon and calibration for accurately sizing the defect.

Read more